Fanuc Alarm 5: NO DATA AFTER ADDRESS
Fanuc Alarm 5: NO DATA AFTER ADDRESS
Fanus Control Model: 16/18/21
Fanuc Alarm Description
The address was not followed by the appropriate data but was followed by another address or EOB code. Modify the program.
Fanuc Alarm 5: NO DATA AFTER ADDRESS
Fanus Control Model: 16/18/21
Fanuc Alarm Description
The address was not followed by the appropriate data but was followed by another address or EOB code. Modify the program.
Fanuc Alarm 5420: ILLEGAL PARAMETER IN G43.4/ G43.5 Fanuc Control Model: 16 / 18 / 21-Series, 16i/18i/21i and 30i/31i/32i series Fanuc Alarm Description A parameter related to pivot tool length compensation is incorrect. Have you faced Fanuc Alarm 5420 ILLEGAL PARAMETER IN G43.4/ G43.5 on your machine? Share your experience or troubleshooting tips in the comments…
Fanuc Alarm 4700: PROGRAM ERROR (OT +) Fanuc Control Model: 16 / 18 / 21-Series, 16i/18i/21i and 30i/31i/32i series Fanuc Alarm Description The value specified in the X-axis move command exceeded the positive value of stored stroke limit 1. (Advance check) Have you faced Fanuc Alarm 4700 PROGRAM ERROR (OT +) on your machine? Share your…
Fanuc Alarm 5311: FSSB:ILLEGAL CONNECTION Fanuc Control Model: 16 / 18 / 21-Series, 16i/18i/21i and 30i/31i/32i series Fanuc Alarm Description A connection related to FSSB is illegal. This alarm is issued when either of the following is found;1. Two axes having adjacent servo axis numbers (parameter No. 1023), odd number and even number, are assigned…
Fanuc Alarm 5057: M–NET BOARD SYSTEM DOWN Fanuc Control Model: 16 / 18 / 21-Series, 16i/18i/21i and 30i/31i/32i series Fanuc Alarm Description Transmission timeout error (parameter No. 177) ROM parity error CPU interrupt other than the above Have you faced Fanuc Alarm 5057 M–NET BOARD SYSTEM DOWN on your machine? Share your experience or troubleshooting tips…
Fanuc Alarm 31: ILLEGAL P COMMAND IN G10 Fanus Control Model: Series 16i / 18i / 21i (Models A and B) and Series 30i / 31i / 32i Description When you use the ‘P’ command incorrectly with a G10 code. The value written after ‘P’ is either outside the offset number that is available in…
Fanuc Alarm 5401: SPL:ILLEGAL COMMAND Fanuc Control Model: 16 / 18 / 21-Series, 16i/18i/21i and 30i/31i/32i series Fanuc Alarm Description In a G code mode in which specification of G06.1 is not permitted, G06.1 is specified. Have you faced Fanuc Alarm 5401 SPL:ILLEGAL COMMAND on your machine? Share your experience or troubleshooting tips in the comments…