Fanuc Alarm 2: TV PARITY ALARM
Fanuc Alarm 2: TV PARITY ALARM
Fanus Control Model: 16/18/21
Fanuc Alarm Description
TV alarm (The number of characters in a block is odd). This alarm will be generated only when the TV check is effective.
Fanuc Alarm 2: TV PARITY ALARM
Fanus Control Model: 16/18/21
Fanuc Alarm Description
TV alarm (The number of characters in a block is odd). This alarm will be generated only when the TV check is effective.
Fanuc Alarm 21: ILLEGAL PLANE AXIS COMMANDED Fanus Control Model: 16/18/21 Fanuc Alarm Description An axis not included in the selected plane (by using G17, G18, G19) was commanded in circular interpolation. Modify the program.
Fanuc Alarm 65: ILLEGAL COMMAND IN G71–G73 Fanus Control Model: 16/18/21 Fanuc Alarm Description T Series;1. G00 or G01 is not commanded at the block with the sequence number which is specified by address P in G71, G72, or G73 command. 2. Address Z(W) or X(U) was commanded in the block with a sequence number…
Fanuc Alarm 71: DATA NOT FOUND Fanus Control Model: 16/18/21 Fanuc Alarm Description The address to be searched was not found. Or the program with specified program number was not found in program number search. Check the data.
Fanuc Alarm 11: NO FEEDRATE COMMANDED Fanus Control Model: 16/18/21 Fanuc Alarm Description Feedrate was not commanded to a cutting feed or the feedrate was inadequate. Modify the program.
Fanuc Alarm 101: PLEASE CLEAR MEMORY Fanus Control Model: Series 0, 16, 18, 21 Description When the power is turned off or the controller suddenly shuts down while writing data to memory (such as loading or editing a program), the part of the memory where the data was stored becomes “corrupted.” How to Fix Alarm…
Fanuc Alarm 6: ILLEGAL USE OF NEGATIVE SIGN Fanus Control Model: 16/18/21 Fanuc Alarm Description Sign “ – ” input error (Sign “ – ” was input after an address with which it cannot be used. Or two or more “ – ” signs were input.) Modify the program.