Fanuc Alarm 10: IMPROPER G–CODE
Fanuc Alarm 10: IMPROPER G–CODE
Fanus Control Model: 16/18/21
Fanuc Alarm Description
An unusable G code or G code corresponding to the function not provided is specified. Modify the program.
Fanuc Alarm 10: IMPROPER G–CODE
Fanus Control Model: 16/18/21
Fanuc Alarm Description
An unusable G code or G code corresponding to the function not provided is specified. Modify the program.
Fanuc Alarm 4: ADDRESS NOT FOUND Fanus Control Model: 16/18/21 Fanuc Alarm Description A numeral or the sign “ – ” was input without an address at the beginning of a block. Modify the program.
Fanuc Alarm 14: CAN NOT COMMAND G95 / ILLEGAL LEAD COMMAND Fanus Control Model: 16/18/21 Fanuc Alarm Description (M Series) A synchronous feed is specified without the option for threading / synchronous feed. (T Series) In variable lead threading, the lead incremental and decremental outputted by address K exceed the maximum command value or a…
Fanuc Alarm 59: PROGRAM NUMBER NOT FOUND Fanus Control Model: 16/18/21 Fanuc Alarm Description In an external program number search, a specified program number was not found. Otherwise, a program specified for searching is being edited in background processing. Alternatively, the program with the program number specified in a one–touch macro call is not found…
Fanuc Alarm 72: TOO MANY PROGRAMS Fanus Control Model: 16/18/21 Fanuc Alarm Description The number of programs to be stored exceeded 63 (basic), 125 (option), 200 (option), or 400 (option) or 1000 (option). Delete unnecessary programs and execute program registration again.
Fanuc Alarm 137: M-CODE & MOVE CMD IN SAME BLK Fanus Control Model: 0 (0-M, 0-T, 0-i) Description An M-code (which is a machine function such as spindle on/off or coolant control) and a ‘Move Command’ (such as X, Y, or Z axis movement) have been combined in a way that is prohibited by Fanuc…
Fanuc Alarm PS067: G70–G73 IN FORBIDDEN MODE Fanus Control Model: Most commonly associated with Fanuc Series 0 (0-T/0-TF) and the Series 16/18/21 Description The control system receives a command in G70, G71, G72, or G73 that is incompatible with its specific mode. This problem usually occurs when you run these Canned Cycles in a sub-program…